Product Identification
Product ID:LUCITE 4F ACRYLIC RESINS
MSDS Date:01/26/1994
FSC:9330
NIIN:00N057835
MSDS Number: CFLRC
Responsible Party
WILMINGTON, DE 19850-5391
US
Emergency Phone: 800-424-9300; 800-228-5635 EXT 181
Info Phone: 302-887-5853
Cage: ICICC
Contractor
Telephone: 800-253-8881 EXT 181
Cage: ICICC
Ingredients
POLYMETHYLMETHACRYLATE; (POLY(METHYL METHACRYLATE)).
CAS: 9011-14-7
RTECS: TR0400000
Fraction By Weight: >99%
OSHA PEL SEE INGREDIENT
ACGIH TLV: SEE INGREDIENT
15 MG/M3
OSHA PEL SEE INGREDIENT
ACGIH TLV: N/K
POTNTL FOR BIOACCUM. PROD IS PREDICTED TO HAVE LOW
RTECS: 9999999ZZ
OSHA PEL SEE INGREDIENT
ACGIH TLV: SEE INGREDIENT
THERE IS NO EVID OF DEGRADATION IN SOIL & WATER. PROD
RTECS: 9999999ZZ
PRODUCT IS ANTICIPATED TO BE POORLY REMOVED IN
RTECS: 9999999ZZ
PROCESSING OF THERMOPLASTICS. TAKE UTMOST CARE.
RTECS: 9999999ZZ
EXTRUSION EQUIP AT MELT TEMPS COULD CAUSE GASEOUS
RTECS: 9999999ZZ
POLYMER FROM NOZZ/DIE W/OUT ANY SCREW MOVEMENT. ALL
RTECS: 9999999ZZ
TEMP, EFT WHICH INCRS W/INCR TEMP. IT IS THEREFORE
RTECS: 9999999ZZ
EVOLVED. HOWEVER, IT IS ONLY MINOR COMPONENTS WHICH
RTECS: 9999999ZZ
"STABILITY & REACTIVITY" SECTION. CARE SHOULD BE
RTECS: 9999999ZZ
EDGES CAN BE SHARP & MAY CAUSE CUTS TO SKIN & DAMAGE
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHALATION:UNLIKELY TO BE
HAZARDOUS BUT DUST OR VAPORS MAY CAUSE IRRITATION. HIGH
CONCENTRATIONS OF DUST MAY BE IRRITANT TO UPPER RESPIRATORY TRACT.
HIGH CONCENTRATIONS OF VAPOR FROM HOT OPERATI ONS MAY BE HARMFUL;
CAUSE IRRITATION OFRESPIRATORY TRACT AND SLIGHT NARCOTIC EFFECTS.
SKIN CONTACT: (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:UNLIKELY TO CAUSE IRRITATION. EYE
CONTACT:DUST MAY CAUSE IRRITATION. INGESTION:LOW ORAL TOXICITY.
CHRONIC:THIS MATERIAL HAS BEEN IN USE FOR MANY YEARS W/NO EVIDENCE
OF ADVERSE EFFECTS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE PATIENT FROM EXPOS. OBTAIN MED ATTN IF ILL EFTS
OCCUR. SKIN:WASH W/SOAP & WATER. MOLTEN MATL CAN CAUSE SEV BURNS.
DO NOT TRY TO PEEL MOLTEN POLYMER FROM SKIN. COOL RAPIDLY W/WATER.
OBTAIN MED ATTN. EYES:REMOVE PARTICLES BY IRRIGATING W/EYE WASH
SOLN/CLEAN WATER FOR AT LST 15 MINS, HOLDING EYELIDS APART. OBTAIN
MED ATTN. INGEST:DO NOT INDUCE VOMIT. WASH OUT MOUTH W/WATER. (SUPP
DATA)
Fire Fighting
Flash Point:572F,300C
Extinguishing Media:WATER SPRAY, FOAM, DRY POWDER OR CO*2.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:COMBUST BUT NOT READILY IGNITED. MAY FORM
EXPLOSIBLE DUST CLOUDS IN AIR. MAY DECOMPOSE IF HEATED >200C.
COMBUST/THERMAL DECOMP WILL EVOLVE TOX, IRRIT & (SUPDAT)
Accidental Release
Spill Release Procedures:CAUT-SPILLAGES MAY BE SLIPPERY. SWEEP UP &
SHOVEL INTO WASTE DRUMS/PLASTIC BAGS. WASH SPILLAGE AREA W/WATER.
ENVIRON FATE & DISTRIBUTION HIGH TONNAGE MATL PRDCD IN PARTIALLY
CNTND SYS. SOLID W/LOW VOL ATILITY. PROD IS ESSNTLY INSOL IN WATER.
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:"LUCITE" ACRYLIC POLYMERS ARE SUPPLIED
IN EITHER BAGS/BULK CNTNRS. KEEP CNTNRS IN CLEAN, COOL & DRY AREA
AWAY FROM HEAT SOURCES. AVOID CONT W/EYES.
Other Precautions:AVOID PRLNG SKIN CONT. AVOID INHAL OF HIGH CONCS OF
DUSTS. EXTRA CARE SHOULD BE TAKEN TO PVNT BURNS FROM CONT W/HOT
MATL. MAY EVOLVE IRRIT FUMES ON PROCESSING/OVERHEATING. PROCESS
HAZS: BURNS ARE MOST COMMON INJURY DURING MELT (ING 6)
Exposure Controls
Respiratory Protection:NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NATURAL VENTILATION IS ADEQUATE.
Protective Gloves:THERMAL INSULATING GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:FLAMM VAPS. FIRST AID PROC:OBTAIN MED ATTN IF ILL EFTS OCCUR.
NOTE:SYMPTOMATIC TREATMENT & SUPPORTIVE THERAPY AS INDICATED. WASTE
DISP METH:PLEASE CONSULT YOUR LOC OFFICE FOR FURTHER DETAILS .
ENSURE THAT ALL PACKAGING IS DISPOSEDOF SAFELY. SPILL PROC:PROD HAS
LOW (ING 3)
Chemical Properties
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BEADS, SOLID GRANULES; TYPICAL "METHACRYLATE" ODOR.
Percent Volatiles by Volume:<1
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:METHYL METHACRYLATE.
Disposal
Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS.
"LUCITE" WASTE IS CONSIDERED TO BE NON-HAZ. CLEAN SCRAP MAY BE
REPROCESSED. INCIN MAY BE USED TO RECOVER ENERGY VALUE. MAY BE DISP
OF BY LANDFILL I/A/W LOC REGS. CERTAIN PACKAGES ARE
RETURNABLE.(SUPDAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.